Pre Vacuum Hphv Steam Sterilizer With Validation Service Port For BSL 3 Laboratory
Specifications:
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.8Y | 680*1180*1000 | 2200*2000*1410 | 1480 | 35 | 280 | 3 |
MD-1.0Y | 680*1180*1250 | 2200*2000*1660 | 1630 | 40 | 300 | 4 |
MD-1.2Y | 680*1180*1500 | 2200*2000*1910 | 2030 | 45 | 320 | 4 |
MD-1.5Y | 680*1180*1870 | 2200*2000*2280 | 2230 | 50 | 350 | 4.5 |
MD-2.0Y | 1000*1200*1700 | 2800*2000*2110 | 2490 | 60 | 400 | 4.5 |
MD-3.0Y | 1000*1500*2000 | 2800*2200*2410 | 3050 | 90 | 500 | 5 |
MD-4.0Y | 1000*1500*2670 | 2800*2200*3080 | 3700 | 120 | 600 | 6 |
MD-5.0Y | 1000*1500*3340 | 2800*2200*3750 | 4600 | 150 | 700 | 8 |
MD-6.0Y | 1000*1500*4000 | 2800*2200*4410 | 5400 | 180 | 800 | 8 |
MD-8.0Y | 1000*1500*5340 | 2800*2200*5750 | 7000 | 240 | 1000 | 12 |
Validation Port
A DN40 validation port with tri-clamp connection for user doing validation conveniently.For big chamber sterilizers, two or three validation ports are available.
Mechanism of killing of microorganisms:
Heat in the form of saturated steam under pressure is the most practical and dependable
agent for sterilization. Bacterial death by moist heat sterilization is due to denaturation and
coagulation of essential protein molecules (enzymes) and cell constituents.
Steam sterilization under pressure is carried out in an autoclave, which is an airtight, jacketed
chamber designed to maintain a high pressure of saturated hot steam. Because the autoclave
permits the attainment of high moist-heat temperatures and because heat exchange by steam
is more rapid than by dry heat, this method of sterilization is more efficient than the dry-heat
method.
Sterilization of aqueous solutions, glassware, and rubber articles is best done by steam under pressure. This process is not suitable for sterilizing solutions of drugs that are thermolabile in nature.
Conditions to be followed for the moist heat sterilization according to standard as below
* Pressure: 15 lb / square inch (psi)
* Temperature: 121 C
* Time: 15 minutes
The latest modularly built MD series sterilizer is suitable for the microbiology, molecular biology, biotechnology and waste decontamination area.
Applications
In the pharmaceutical, life science, biotechnology, laboratory, and animal care markets
Custom Engineering
1. In many complex biomedical laboratories and pharmaceutical facilities, a basic sterilizer
will not suffice.
2. Select the options and accessories you need, and let our talented team of engineers design
a sterilizer to meet all of your requirements.