Add to Cart
Features
Automatic sliding doors with safety edge and auto-reverse system.
Pre/post vacuum system Air detector.
Steam jacket for optimum drying performance
8-program user-friendly touch screen control system.
Thermal data printer
E-Stop
Clean steam option
A part of size for selection
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.11V | 400*400*700 | 1000*1800*1040 | 650 | 14 | 15 | 2 |
MD-0.16V | 400*400*1000 | 1000*1800*1340 | 700 | 16 | 20 | 2 |
MD-0.20V | 400*400*1300 | 1000*1800*1640 | 750 | 18 | 25 | 2 |
MD-0.24V | 600*600*670 | 1200*2000*1010 | 800 | 20 | 30 | 2 |
MD-0.30V | 600*600*840 | 1200*2000*1180 | 850 | 22 | 35 | 2 |
MD-0.36V | 600*600*1000 | 1200*2000*1340 | 900 | 25 | 40 | 2 |
MD-0.45V | 600*600*1250 | 1200*2000*1590 | 980 | 27 | 50 | 2 |
MD-0.60V | 600*600*1670 | 1200*2000*2010 | 1100 | 30 | 60 | 3 |
Description
• Our range of porous load rectangular chambered sterilizers are available in six standard sizes
and 110 to 600 liters.
• All models can be configured for either single entry or pass-through. All models are fitted with a
wide selection of features as standard, all designed to ensure optimum performance and the
fastest possible cycle times.
• In addition to traditional loading trolley systems, Medpharm is also able to provide assisted and
automated loading solutions.
• Pass-Through: Available throughout range
• Section: Square or Rectangular
• Loading: Front
• Heating Source: Integral/stand-alone steam generator or direct steam supply
Cycles
Cycle name | Further details | Application |
Instruments/Tools | 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. | Solid materials to be sterilized: ●Packaged instruments ●Empty glass containers ●Empty metal containers Porous materials to be sterilized: ●Rubber articles |
Clothing | 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. | Materials to be sterilized from which air can’t be easily displaced ●Textile |
User Programmable | All preset parameters can be reset; Multiple customized programs can be set and stored by user. | Customized |
Test cycles | ||
B-D Test | 3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. | Test program |
Vacuum Leak Test | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. | Test program |
Popular Options
1. Loading/Carriage Trolleys
2. Stainless steel pipe work Independent monitoring
3. Air Compressor
4. RO water system
5. Remote data archiving