Automatic Hinge Door CSSD Sterilizer 1000 Liter With Safety Working System
Features
· The inner chamber is fabricated from S.S. 316 or S.S. 316L and is fully welded to ensure a crevice free and easy to clean environment.
· Temperature Uniformity +/- 1 degree Celsius guaranteed within the chamber for the entire cycle.
· Air filter of 99.97% performance for clean air.
· Positive Pressure throughout the cycle for 100% Sterile integrity of the load.
· Automatic PLC controlled cycle with user-friendly operator interface for visual monitor and control over the entire cycle.
· Blind Temperature Controller for overshoots temperature condition.
· Automatic F0 Calculator with facility for control in case of heat labile materials.
· On-line printing for process documentation.
· With stainless steel trays,safety and easy to clean
· Pneumatic valves
Specifications
Model | MD-1.0 |
Door number | Double door |
Door type | Motorized Hinge Door |
Chamber volume | 1000 liters |
Chamber Size | 680*1180*1250mm |
Overall Size | 1450*2000*1590mm |
Net Weight | 1550kg |
Steam | 40Kg/cycle |
Water | 100Kg/cycle |
Power(KVA) | 4KVA |
Sterilization temperature rage | 105°C to 134°C |
Sterilization time rage | 0---99 minutes |
Vacuum times | 0---9 times |
Drying time | 0---99 minutes |
Steam feeding | External steam supply, 0.4---0.7MPa, saturated steam offer by user |
Combining steam generators: individual electrically heated steam generators or natural gas heated steam generators |
Safety working system Benefits
· In case of power failure, the steam inlet is closed.
· In case of excess steam pressure, the steam inlet is closed and safety release valve is open.
· Safety valve normalized and calibrated at 2.5 kgf/cm² with cleaning and operation inspection device.
· Start of cycle only if there is steam pressure in the generator or in the supply line.
· Automatic door elevation system with calibrated working pressure for the operator’s safety.
· Opening the doors is impossible after the start of the cycle and if there is steam pressure in the chamber
· Opening the two doors simultaneously by the operator is impossible (barrier sterilizers).
· Blocking of exposure time count in case of lack of temperature defined for the cycle in the chamber.
· Safety thermostat for the protection of electrical heaters.
· Emergency routine that in case of power failure maintains the doors locked and releases the chamber steam pressure.
· Emergency button on the equipment panel to turn off the sterilizer and depressurization of the sterilization chamber.
· Door with anti-crush system, which interrupts the movement of the door if it is obstructed.
· Mechanical lock which prevents the opening of the door when the sterilizer is in operation.