Add to Cart
Over Temperature Protection Hospital Steam Sterilizer With Automatic Loading And Unloading System
1. Fully stainless steel structure
2. Hand wheel type of quick-open door structure
3. Door safety lock system
4. LCD digital display of working status,touch of key
5. Auto discharge the cool air,and steam discharging auto matically after sterilization
6. Over temperature&over pressure auto-protection
7. Safe protection of water lacking
8. Self-inflating type seal
9. Automatically shut off with beep reminding after sterilization
10. With two stainless steel sterilizing baskets
11. The drying system is optional, which can be equipped according to the customers request
12. Easy to operate, safe and reliable
Specification
Model | Chamber Size | Overall Size | Net Weight | Steam | Water | Power |
W*H*D mm | W*H*D mm | Kg | Kg/cycle | Kg/cycle | KVA | |
MD-0.8Y | 680*1180*1000 | 2200*2000*1410 | 1480 | 35 | 80 | 3 |
MD-1.0Y | 680*1180*1250 | 2200*2000*1660 | 1630 | 40 | 100 | 4 |
MD-1.2Y | 680*1180*1500 | 2200*2000*1910 | 2030 | 45 | 120 | 4 |
MD-1.5Y | 680*1180*1870 | 2200*2000*2280 | 2230 | 50 | 150 | 4.5 |
MD-2.0Y | 1000*1200*1700 | 2800*2000*2110 | 2490 | 60 | 200 | 4.5 |
MD-3.0Y | 1000*1500*2000 | 2800*2200*2410 | 3050 | 90 | 300 | 5 |
MD-4.0Y | 1000*1500*2670 | 2800*2200*3080 | 3700 | 120 | 400 | 6 |
MD-5.0Y | 1000*1500*3340 | 2800*2200*3750 | 4600 | 150 | 500 | 8 |
MD-6.0Y | 1000*1500*4000 | 2800*2200*4410 | 5400 | 180 | 600 | 8 |
MD-8.0Y | 1000*1500*5340 | 2800*2200*5750 | 7000 | 240 | 800 | 12 |
Program Parameter
Cycle name | Further details | Application |
Instruments/Tools | 3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. | Solid materials to be sterilized: |
Clothing | 3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min. | Materials to be sterilized from which air can’t be easily displaced |
User Programmable | All preset parameters can be reset; Multiple customized programs can be set and stored by user. | Customized |
Test programs | ||
B-D Test | 3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. | Test program |
Vacuum Leak Test | Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect. | Test program |
Description
- Cycle phases and parameters, both in the numerical and trend form
- Anomalies, alarms
- Main components maintenance status
Applications
• Packaged instruments
• Empty glass containers
• Empty metal containers
• Textiles
• Rubber articles
Competitive Advantage
Well thought-out designs and the professionalism of our experts guarantee high-tech
chamber construction.
The high quality level is based on facts: ruggedness of the doors and their actuating system, precision groove for guidance of the solid silicone seal with a long service life, use of high-quality materials in conjunction with ultra-modern production technology.
Automatic loading and unloading system.
An entire series of modular elements is available for a largely automated operation of the sterilizer: automatic loading and unloading units, with or without accumulating sections of various sizes and return locks of either single or two-door design.